Spectrogram (SSID 24, L4) timing information issues #424

Description

@samaloney

While investigating some potential FSW bugs it was discovered that the spectrogram bin edges derived from the fits files are not contiguous, there are small under and overlaps.

  • Confirmed this is present in the raw TM so not ground processing issue
  • Investigation found the reported closing time offset (NIX00029) is not accurate between science substructures
  • Simple fix was to stack all start times and only use the closing time offset (NIX00029) for the last science substructures
  • Unclear if closing time offset (NIX00029) should be valid for all substructures or only last but don't need to know for this fix